Program > Output Options
Cutoff Time: If you assign a Cutoff Output, then you may enter a Cutoff Time from 1 to 99 minutes
(in 1-minute increments) for the output to remain on. Enter 0 (zero) for continuous output.
Communication Fail Output: Enter the output number to turn on when the iCOMsl has attempted to
transmit a message for 60 seconds to the receiver without success. enter 0 (zero) to disable this
output. The default value is 0 (zero). The communication Fail Output turns off when communication
with the receiver restores.
Closing Wait Output: Enter the output number to turn on for four (4) seconds when Closing Wait is
programmed as YES and the iCOMsl successfully communicates the closing message at arming. If the
closing message does not communicate successfully, this output does not turn on.
Program > Output Information