Additional Outputs for XR200, XR200-485(B), XR2400F
Outputs for iCOMsl
Output Information
Program > Output Options
Armed Output: Enter the output number to turn on when any area is armed. The output is turned off
when the entire system is disarmed.
Burglary Output: Enter the output number to turn on any time a burglary type zone is placed into
alarm. The output is turned off when the user disarms the area where the alarm occurred.
Program > Output Options
The Output Options window allows you to enable the XRSuper6, XR20, or XR40 alarm output by
selecting a cadence for each zone type.
Armed Output: Enter the output number to turn on when any area is armed. The output is turned off
when the entire system is disarmed.
Burglary Output: Enter the output number to turn on any time a burglary type zone is placed into
alarm. The output is turned off when the user disarms the area where the alarm occurred.
Ground Start Output: Enter the output number to turn on for 750ms any time that the panel seizes
the telephone line. This output is used when connecting to a ground start phone system.
Cell Backup Output: When connected to a double-pole, double-throw relay, this option allows cellular
communication with Cell-Miser restrictions.