Strona 1 - PROGRAMMING GUIDE

PROGRAMMING GUIDEXR500 SERIES CANADIAN COMMAND PROCESSOR™ PANEL

Strona 2 - COMMAND PROCESSOR™ PANEL

XR500 Series Canadian Programming Guide Digital Monitoring Products1INTRODUCTIONIntroduction1.1 Before you BeginThis guide provides programming info

Strona 3 - TABLE OF CONTENTS

Digital Monitoring Products XR500 Series Canadian Programming Guide2INTRODUCTION1.3 Encrypted Communications (XR500N/XR500E only)Some installations

Strona 4

XR500 Series Canadian Programming Guide Digital Monitoring Products3INTRODUCTION1.8 Keypads DMP offers multiple keypads in a variety of styles. All

Strona 5

Digital Monitoring Products XR500 Series Canadian Programming Guide4INTRODUCTION1.11 Entering Non-Alpha CharactersToenteraspaceinanalphaentry

Strona 6

XR500 Series Canadian Programming Guide Digital Monitoring Products5INTRODUCTION1.14 Asterisks in ProgrammingAsterisks display next to a programming

Strona 7

Digital Monitoring Products XR500 Series Canadian Programming Guide6INITIALIZATIONInitializationNOTE: WHEN ANY PANEL PROGRAMMING IS CHANGED, THE STO

Strona 8

XR500 Series Canadian Programming Guide Digital Monitoring Products7INITIALIZATION2.9 COM/RMT? NO YESSURE? YES NO Clear Communication and Remot

Strona 9

Digital Monitoring Products XR500 Series Canadian Programming Guide8COMMUNICATIONCommunication3.1 COMMUNICATION CommunicationCongurethecommunicati

Strona 10 - Introduction

XR500 Series Canadian Programming Guide Digital Monitoring Products9COMMUNICATION3.6 PATH TYPE: BACKUP Path TypeThePathTypedenesifthepathis

Strona 11

Digital Monitoring Products XR500 Series Canadian Programming Guide10COMMUNICATION3.15 RECEIVER PORT - Receiver Port 2001 Entertherece

Strona 12 - FRI 12:51

MODEL XR500 SERIES CANADIAN ACCESS CONTROL COMMAND PROCESSOR™ PANELPROGRAMMING GUIDEContains programming Instructions for use with the Model XR500, X

Strona 13 - NOBELL TST

XR500 Series Canadian Programming Guide Digital Monitoring Products11COMMUNICATION3.22 RETRY SECONDS: 6 Retry SecondsThis option displays for NET or

Strona 14 - INTRODUCTION

Digital Monitoring Products XR500 Series Canadian Programming Guide12COMMUNICATION3.29 ALARM YES Alarm ReportsThis prompt displays when the Pa

Strona 15 - Initialization

XR500 Series Canadian Programming Guide Digital Monitoring Products13NETWORK OPTIONSNetwork Options (XR500N/XR500E only)NetworkOptionsareprovided

Strona 16 - INITIALIZATION

Digital Monitoring Products XR500 Series Canadian Programming Guide14MESSAGING SETUPMessaging Setup5.1 MESSAGING SETUP Messaging Setup This section

Strona 17 - Communication

XR500 Series Canadian Programming Guide Digital Monitoring Products15MESSAGING SETUP5.9 Destination 3 User Number If Destination 3 is a cellular

Strona 18 - 000.000.000.000

Digital Monitoring Products XR500 Series Canadian Programming Guide16DEVICE SETUPDevice Setup6.1 DEVICE SETUP Device SetupThissectionallowsyouto

Strona 19

XR500 Series Canadian Programming Guide Digital Monitoring Products17DEVICE SETUPIf you do not enter any area numbers, all users with Door Access aut

Strona 20

Digital Monitoring Products XR500 Series Canadian Programming Guide18DEVICE SETUP• DoorScheduleschangesareallowedfordevicesthathaveamatchi

Strona 21 - PANIC TST NO YES

XR500 Series Canadian Programming Guide Digital Monitoring Products19DEVICE SETUP6.13 OVERRIDE NO YES Schedule OverrideUsethisoptiontoallowdoo

Strona 22 - (XR500N/XR500E only)

Digital Monitoring Products XR500 Series Canadian Programming Guide20DEVICE SETUP6.18.3 RELOCK ON ZONE 2CHANGE? NO YES Relock on Zone 2 Change?Sele

Strona 23 - Messaging Setup

XR500 Series Canadian Programming Guide Digital Monitoring ProductsiTABLE OF CONTENTS1.1 Before you Begin ...

Strona 24

XR500 Series Canadian Programming Guide Digital Monitoring Products21DEVICE SETUP 734 Site Code Programming6.18.9 Site Code PositionEnter the si

Strona 25 - Device Setup

Digital Monitoring Products XR500 Series Canadian Programming Guide22REMOTE OPTIONS6.18.15 No Communication with PanelThisoptiondenestherelaya

Strona 26

XR500 Series Canadian Programming Guide Digital Monitoring Products23REMOTE OPTIONS7.6 PC Modem YESallowsthepaneltoanswerthetelcoli

Strona 27

Digital Monitoring Products XR500 Series Canadian Programming Guide24REMOTE OPTIONS7.11.2 Encrypt Cellular RemoteYES encrypts data sent over a cell

Strona 28

XR500 Series Canadian Programming Guide Digital Monitoring Products25SYSTEM REPORTS7.14.1 REMOTE CHANGE IP Remote Change IPThisoptiondisplayswhen

Strona 29

Digital Monitoring Products XR500 Series Canadian Programming Guide26SYSTEM REPORTS8.6 CODE CHG NO YES Code Change ReportsYES allows the panel to s

Strona 30 - 01110101101101010001100111

XR500 Series Canadian Programming Guide Digital Monitoring Products27SYSTEM OPTIONSSystem Options9.1 SYSTEM OPTIONS System OptionsThissectionallows

Strona 31 - Remote Options

Digital Monitoring Products XR500 Series Canadian Programming Guide28SYSTEM OPTIONS9.6 CRS ZONE TM: 4 Cross Zone TimeEnter the time allowed between

Strona 32

XR500 Series Canadian Programming Guide Digital Monitoring Products29SYSTEM OPTIONS9.12 LATCH SV NO YES Latch Supervisory ZonesSelecting YES latch

Strona 33

Digital Monitoring Products XR500 Series Canadian Programming Guide30SYSTEM OPTIONS9.16 CARD PLUS PIN: NO YES Card Plus PIN (XR500E only)Select YES

Strona 34 - System Reports

Digital Monitoring Products XR500 Series Canadian Programming GuideiiTABLE OF CONTENTS4.3 Gateway Address ...

Strona 35

XR500 Series Canadian Programming Guide Digital Monitoring Products31SYSTEM OPTIONS9.22 ENHANCED ZONE TEST: NO YES Enhanced Zone TestSelect

Strona 36 - System Options

Digital Monitoring Products XR500 Series Canadian Programming Guide32SYSTEM OPTIONS9.27 PANIC SUPERVISION: NO YES Panic SupervisionSelectYESto

Strona 37

XR500 Series Canadian Programming Guide Digital Monitoring Products33BELL OPTIONSBell Options10.1 BELL OPTIONS Bell OptionsThis section allows yo

Strona 38

Digital Monitoring Products XR500 Series Canadian Programming Guide34OUTPUT OPTIONSOutput Options11.1 OUTPUT OPTIONS Output OptionsThis section allo

Strona 39

XR500 Series Canadian Programming Guide Digital Monitoring Products35OUTPUT OPTIONS11.6 PANIC ALM OUT: 0 Panic Alarm OutputEnter the output numb

Strona 40

Digital Monitoring Products XR500 Series Canadian Programming Guide36OUTPUT OPTIONS11.15 CLS WAIT OUT: 0 Closing Wait OutputEntertheoutputnu

Strona 41 - Panic Supervision

XR500 Series Canadian Programming Guide Digital Monitoring Products37OUTPUT INFORMATIONOutput Information12.1 OUTPUT INFO Output InformationThis

Strona 42 - Bell Options

Digital Monitoring Products XR500 Series Canadian Programming Guide38OUTPUT GROUPSOutput Groups13.1 OUTPUT GROUPS Output GroupsThis function allows y

Strona 43 - Output Options

XR500 Series Canadian Programming Guide Digital Monitoring Products39MENU DISPLAYMenu Display14.1 MENU DISPLAY Menu Display Menu Display allows you t

Strona 44

Digital Monitoring Products XR500 Series Canadian Programming Guide40STATUS LISTStatus List15.1 STATUS LIST Status List This function allows you to s

Strona 45 - Supervisory Alarm Output

XR500 Series Canadian Programming Guide Digital Monitoring ProductsiiiTABLE OF CONTENTS7.4 Armed Answer Rings ...

Strona 46 - Output Information

XR500 Series Canadian Programming Guide Digital Monitoring Products41STATUS LIST15.5 BURGLARY ZONES: Burglary ZonesSpeciesthekeypadaddresses(1t

Strona 47 - Output Groups

Digital Monitoring Products XR500 Series Canadian Programming Guide42PRINTER REPORTSPrinter Reports16.1 PRINTER REPORTS Printer ReportsThissectiona

Strona 48 - Menu Display

XR500 Series Canadian Programming Guide Digital Monitoring Products43PC LOG REPORTSPC Log Reports17.1 PC LOG REPORTS PC Log ReportsThissectionallow

Strona 49 - Status List

Digital Monitoring Products XR500 Series Canadian Programming Guide44PC LOG REPORTS17.10 DOOR ACS NO YES Door Access ReportsSends door access activi

Strona 50

XR500 Series Canadian Programming Guide Digital Monitoring Products45AREA INFORMATION Area Information18.1 AREA INFORMATION Area InformationAllowsyo

Strona 51 - Printer Reports

Digital Monitoring Products XR500 Series Canadian Programming Guide46AREA INFORMATION18.5 CLS CHK NO YES Closing CheckSelect YES to enable the panel

Strona 52 - PC Log Reports

XR500 Series Canadian Programming Guide Digital Monitoring Products47AREA INFORMATION 18.10.1 All/Perimeter ProgrammingWhenAll/Perimeterisselect

Strona 53

Digital Monitoring Products XR500 Series Canadian Programming Guide48AREA INFORMATION18.16 ARMED OUTPUT: 0 Armed Output NumberEnter the output to t

Strona 54 - Area Information

XR500 Series Canadian Programming Guide Digital Monitoring Products49ZONE INFORMATION Zone Information19.1 ZONE INFORMATION Zone InformationZoneInfo

Strona 55

Digital Monitoring Products XR500 Series Canadian Programming Guide50ZONE INFORMATION19.4 ZONE TYPE: BLANK Zone TypeTheZoneTypedenesthepanel

Strona 56

Digital Monitoring Products XR500 Series Canadian Programming GuideivTABLE OF CONTENTS10.4 Bell Output ...

Strona 57

XR500 Series Canadian Programming Guide Digital Monitoring Products51ZONE INFORMATION When the zone changes from normal to shorted, the programmed ar

Strona 58 - Zone Information

Digital Monitoring Products XR500 Series Canadian Programming Guide52ZONE INFORMATION19.9 NEXT ZN? NO YES Next ZoneSelect YES to terminate zone pro

Strona 59

XR500 Series Canadian Programming Guide Digital Monitoring Products53ZONE INFORMATION consecutive zone numbers. Default is Contact 1. Forexample,u

Strona 60

Digital Monitoring Products XR500 Series Canadian Programming Guide54ZONE INFORMATION1100 Series Key FobsFor an 1100 Series Key Fob set the House Cod

Strona 61

XR500 Series Canadian Programming Guide Digital Monitoring Products55ZONE INFORMATION 19.11.7 BUTTON ACTION yyy: XXXXXXXX Button ActionThisopt

Strona 62

Digital Monitoring Products XR500 Series Canadian Programming Guide56ZONE INFORMATION ARM AREAS: PERIM InanAll/PerimeterorHome/Sleep/Awaysys

Strona 63

XR500 Series Canadian Programming Guide Digital Monitoring Products57ZONE INFORMATION FA Series Wireless For an FA Series Remote Wireless Receiver se

Strona 64

Digital Monitoring Products XR500 Series Canadian Programming Guide58ZONE INFORMATION19.15 MSG: TROUBLE Report to TransmitPressanySelectke

Strona 65 - Output Number

XR500 Series Canadian Programming Guide Digital Monitoring Products59ZONE INFORMATION FOLLOW - The output is turned on and remains on while the zone

Strona 66 - Normally Open

Digital Monitoring Products XR500 Series Canadian Programming Guide60ZONE INFORMATION19.24 CRS ZONE NO YES Cross ZoneSelect YES to enable cross zoni

Strona 67

XR500 Series Canadian Programming Guide Digital Monitoring ProductsvTABLE OF CONTENTSPC Log Reports ...

Strona 68

XR500 Series Canadian Programming Guide Digital Monitoring Products61STOPSET LOCKOUT CODEStop20.1 STOP StopSave ProgrammingWHEN ANY PANEL PROGRAMMING

Strona 69 - Door Number

Digital Monitoring Products XR500 Series Canadian Programming Guide62FEATURE UPGRADEFeature Upgrade22.1 FEATURE UPGRADE Feature UpgradeIntheProgram

Strona 70 - Set Lockout Code

XR500 Series Canadian Programming Guide Digital Monitoring Products63APPENDIXAppendix23.1 False Alarm ReductionSystem Recently Armed reportTheSyste

Strona 71 - Feature Upgrade

Digital Monitoring Products XR500 Series Canadian Programming Guide64APPENDIXSerial NumberThisnumberisthenetworkcommunicatorserialnumber.Ref

Strona 72 - Appendix

XR500 Series Canadian Programming Guide Digital Monitoring Products65APPENDIXExiting the Diagnostics programPress the COMMAND key until STOP displays

Strona 73 - APPENDIX

Digital Monitoring Products XR500 Series Canadian Programming Guide66APPENDIXNote: If the Panic Supervision option is enabled in SYSTEM OPTIONS, the

Strona 74 - 23.4 Using the Walk Test

XR500 Series Canadian Programming Guide Digital Monitoring Products67APPENDIXEND - SelectENDtostoptheWalkTest.WhentheWalkTestendsora20

Strona 75

Digital Monitoring Products XR500 Series Canadian Programming Guide68APPENDIX23.6 Cross ZoningCaution must be taken when cross zoning devices to ens

Strona 76

XR500 Series Canadian Programming Guide Digital Monitoring Products69APPENDIX23.9 UserProlesRecordThisUserProlesRecordcanbeusedasatool

Strona 77 - 23.8 UserProles

Digital Monitoring Products XR500 Series Canadian Programming Guide70APPENDIX23.10.1WirelessCheck-inandSupervisionDenitions FA Series Check-i

Strona 78 - 23.9 UserProlesRecord

Digital Monitoring Products XR500 Series Canadian Programming GuideviTABLE OF CONTENTS19.11.11 Output Action ...

Strona 79

XR500 Series Canadian Programming Guide Digital Monitoring Products71APPENDIX23.12 ZoneTypeSpecicationsTheXR500SeriesCanadianpanelcontains

Strona 80 - Keypad Bus Zone Type Defaults

Digital Monitoring Products XR500 Series Canadian Programming Guide72APPENDIX23.12.2 LX-Bus Zone Type DefaultsThese are complete spellings of the abb

Strona 81 - LX-Bus Zone Type Defaults

XR500 Series Canadian Programming Guide Digital Monitoring Products73APPENDIX23.13 Common Keypad MessagesThere are several common keypad messages th

Strona 82 - 23.13 Common Keypad Messages

Digital Monitoring Products XR500 Series Canadian Programming Guide74APPENDIX23.14 Area Account Number Messages XR500 systems send an area account n

Strona 83

XR500 Series Canadian Programming Guide Digital Monitoring Products75REVISIONSRevisions to This DocumentThissectionexplainsthechangesmadetothi

Strona 84 - Revisions to This Document

LT-0679CAN 1.14 © 2012 Digital Monitoring Products, Inc.800-641-4282www.dmp.comMade in the USAINTRUSION•FIRE•ACCESS•NETWORKS2500 North Partnersh

Strona 85 - Listings and Approvals

XR500 Series Canadian Programming Guide Digital Monitoring ProductsviiThis page intentionally left blank.